A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 3012B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 3012B (TDS3012B)   Description / Specification:    
TEKTRONIX TDS 3012B 2 Ch 100 MHz Digital Phosphor Oscilloscope

100 MHz, Digital Phosphor Oscilloscope, Two Channel. Sample Rate on Each Channel: 1.25 GS/s. Maximum record length: 10 K points on all models. Vertical resolution: 9 Bits on all models. Vertical sensitivity (/div): 1 mV – 10 V on all models. Vertical accuracy: ±2% on all models. Max input voltage (1 M-Ohm): 150 VRMS CAT I on all models (300 V CAT II with standard 10X probe). Position range: ± 5 div on all models. BW limit: 20 MHz. Input coupling: AC, DC, GND. Input impedance selections: 1 M-Ohm in parallel with 13 pF or 50 ohm. Time base Range: 4 ns – 10 s/div. Time base Accuracy: 20 ppm. Trigger System; Main Trigger Modes: Auto (supports Roll Mode for 40 ms/div and slower), Normal. B Trigger: Trigger after time or events. Trigger After Time Range: 13.2 ns to 50 s. Trigger After Events Range: 1 to 9,999,999 events. External Trigger Input: >1 M- Ohm in parallel with 17 pF; Max input voltage is 150 VRMS. Trigger Types; Edge: Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: DC, noise reject, HF reject, LF reject. Video: Trigger on all lines, odd, even or all fields. With TDS3VID or TDS3SDI, trigger on individual lines and on analog HDTV formats (1080i, 1080p, 720p, 480p). Display (VGA) Color active matrix LCD



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 3012B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your TEKTRONIX TDS 3012B CALIBRATION and/or TEKTRONIX TDS 3012B 2 Ch 100 MHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: